Review



ecog platinum ground wire pfa-coated platinum wire ( bare diameter)  (A-M Systems)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    A-M Systems ecog platinum ground wire pfa-coated platinum wire ( bare diameter)
    Ecog Platinum Ground Wire Pfa Coated Platinum Wire ( Bare Diameter), supplied by A-M Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/ecog platinum ground wire pfa-coated platinum wire ( bare diameter)/product/A-M Systems
    Average 90 stars, based on 1 article reviews
    ecog platinum ground wire pfa-coated platinum wire ( bare diameter) - by Bioz Stars, 2026-06
    90/100 stars

    Images



    Similar Products

    90
    A-M Systems ecog platinum ground wire pfa-coated platinum wire ( bare diameter)
    Ecog Platinum Ground Wire Pfa Coated Platinum Wire ( Bare Diameter), supplied by A-M Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/ecog platinum ground wire pfa-coated platinum wire ( bare diameter)/product/A-M Systems
    Average 90 stars, based on 1 article reviews
    ecog platinum ground wire pfa-coated platinum wire ( bare diameter) - by Bioz Stars, 2026-06
    90/100 stars
      Buy from Supplier

    86
    A-M Systems ground platinum wire
    Ground Platinum Wire, supplied by A-M Systems, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/ground platinum wire/product/A-M Systems
    Average 86 stars, based on 1 article reviews
    ground platinum wire - by Bioz Stars, 2026-06
    86/100 stars
      Buy from Supplier

    86
    A-M Systems ecog platinum ground wire
    a , Left: schematic of an NHP brain. The soft ABI is implanted on the cochlear nucleus; the soft <t>ECoG</t> records cortical responses from the auditory cortex. Right: NHP behavioural task in response to electrical or acoustic stimulation. Created with BioRender.com ( https://BioRender.com/y29o453 ) and using a brain image from Adobe Stock. b , Photograph of the integrated soft ABI and its connectors: an Omnetics connector is embedded in a PEEK pedestal and connected to the soft ABI. An imaging marker and resorbable insertion spine are also visible. c , Integrated soft ECoG device: 29 electrodes (300-µm diameter) that record cortical signals. d , Close-up of the soft ABI: 11 electrodes (100-µm diameter). Right inset: FlexComb connector . e , f , In vitro characterization of the soft ABI ( e ) and EcoG ( f ). Left: EIS measurement, where data points represent the average and bars represent standard errors for all electrodes. Right: VT in response to a 100-µA biphasic current pulse. The thick blue line represents the average and light lines represent individual electrodes. g , Scanning electron microscopy (SEM) images of micropatterned ABI electrodes and interconnects. Top left: image of one ABI electrode and associated interconnect. Red frame, close-up of an interconnect; green frame, close-up of the electrode. Bottom right: colourized SEM of the electrode and encapsulation of <t>the</t> <t>platinum</t> layer within the polyimide dielectric layers.
    Ecog Platinum Ground Wire, supplied by A-M Systems, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/ecog platinum ground wire/product/A-M Systems
    Average 86 stars, based on 1 article reviews
    ecog platinum ground wire - by Bioz Stars, 2026-06
    86/100 stars
      Buy from Supplier

    90
    PlasticsOne inc twisted bipolar platinum electrodes with a ground wire ms333/8-biu/spc
    a , Left: schematic of an NHP brain. The soft ABI is implanted on the cochlear nucleus; the soft <t>ECoG</t> records cortical responses from the auditory cortex. Right: NHP behavioural task in response to electrical or acoustic stimulation. Created with BioRender.com ( https://BioRender.com/y29o453 ) and using a brain image from Adobe Stock. b , Photograph of the integrated soft ABI and its connectors: an Omnetics connector is embedded in a PEEK pedestal and connected to the soft ABI. An imaging marker and resorbable insertion spine are also visible. c , Integrated soft ECoG device: 29 electrodes (300-µm diameter) that record cortical signals. d , Close-up of the soft ABI: 11 electrodes (100-µm diameter). Right inset: FlexComb connector . e , f , In vitro characterization of the soft ABI ( e ) and EcoG ( f ). Left: EIS measurement, where data points represent the average and bars represent standard errors for all electrodes. Right: VT in response to a 100-µA biphasic current pulse. The thick blue line represents the average and light lines represent individual electrodes. g , Scanning electron microscopy (SEM) images of micropatterned ABI electrodes and interconnects. Top left: image of one ABI electrode and associated interconnect. Red frame, close-up of an interconnect; green frame, close-up of the electrode. Bottom right: colourized SEM of the electrode and encapsulation of <t>the</t> <t>platinum</t> layer within the polyimide dielectric layers.
    Twisted Bipolar Platinum Electrodes With A Ground Wire Ms333/8 Biu/Spc, supplied by PlasticsOne inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/twisted bipolar platinum electrodes with a ground wire ms333/8-biu/spc/product/PlasticsOne inc
    Average 90 stars, based on 1 article reviews
    twisted bipolar platinum electrodes with a ground wire ms333/8-biu/spc - by Bioz Stars, 2026-06
    90/100 stars
      Buy from Supplier

    90
    A-M Systems platinum ground wire (0.003 in dia., teflon coating; am-systems)
    a , Left: schematic of an NHP brain. The soft ABI is implanted on the cochlear nucleus; the soft <t>ECoG</t> records cortical responses from the auditory cortex. Right: NHP behavioural task in response to electrical or acoustic stimulation. Created with BioRender.com ( https://BioRender.com/y29o453 ) and using a brain image from Adobe Stock. b , Photograph of the integrated soft ABI and its connectors: an Omnetics connector is embedded in a PEEK pedestal and connected to the soft ABI. An imaging marker and resorbable insertion spine are also visible. c , Integrated soft ECoG device: 29 electrodes (300-µm diameter) that record cortical signals. d , Close-up of the soft ABI: 11 electrodes (100-µm diameter). Right inset: FlexComb connector . e , f , In vitro characterization of the soft ABI ( e ) and EcoG ( f ). Left: EIS measurement, where data points represent the average and bars represent standard errors for all electrodes. Right: VT in response to a 100-µA biphasic current pulse. The thick blue line represents the average and light lines represent individual electrodes. g , Scanning electron microscopy (SEM) images of micropatterned ABI electrodes and interconnects. Top left: image of one ABI electrode and associated interconnect. Red frame, close-up of an interconnect; green frame, close-up of the electrode. Bottom right: colourized SEM of the electrode and encapsulation of <t>the</t> <t>platinum</t> layer within the polyimide dielectric layers.
    Platinum Ground Wire (0.003 In Dia., Teflon Coating; Am Systems), supplied by A-M Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/platinum ground wire (0.003 in dia., teflon coating; am-systems)/product/A-M Systems
    Average 90 stars, based on 1 article reviews
    platinum ground wire (0.003 in dia., teflon coating; am-systems) - by Bioz Stars, 2026-06
    90/100 stars
      Buy from Supplier

    90
    Omnetics Connector Corporation platinum ground and reference wires
    a , Left: schematic of an NHP brain. The soft ABI is implanted on the cochlear nucleus; the soft <t>ECoG</t> records cortical responses from the auditory cortex. Right: NHP behavioural task in response to electrical or acoustic stimulation. Created with BioRender.com ( https://BioRender.com/y29o453 ) and using a brain image from Adobe Stock. b , Photograph of the integrated soft ABI and its connectors: an Omnetics connector is embedded in a PEEK pedestal and connected to the soft ABI. An imaging marker and resorbable insertion spine are also visible. c , Integrated soft ECoG device: 29 electrodes (300-µm diameter) that record cortical signals. d , Close-up of the soft ABI: 11 electrodes (100-µm diameter). Right inset: FlexComb connector . e , f , In vitro characterization of the soft ABI ( e ) and EcoG ( f ). Left: EIS measurement, where data points represent the average and bars represent standard errors for all electrodes. Right: VT in response to a 100-µA biphasic current pulse. The thick blue line represents the average and light lines represent individual electrodes. g , Scanning electron microscopy (SEM) images of micropatterned ABI electrodes and interconnects. Top left: image of one ABI electrode and associated interconnect. Red frame, close-up of an interconnect; green frame, close-up of the electrode. Bottom right: colourized SEM of the electrode and encapsulation of <t>the</t> <t>platinum</t> layer within the polyimide dielectric layers.
    Platinum Ground And Reference Wires, supplied by Omnetics Connector Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/platinum ground and reference wires/product/Omnetics Connector Corporation
    Average 90 stars, based on 1 article reviews
    platinum ground and reference wires - by Bioz Stars, 2026-06
    90/100 stars
      Buy from Supplier

    90
    A-M Systems platinum iridium ground wire
    a , Left: schematic of an NHP brain. The soft ABI is implanted on the cochlear nucleus; the soft <t>ECoG</t> records cortical responses from the auditory cortex. Right: NHP behavioural task in response to electrical or acoustic stimulation. Created with BioRender.com ( https://BioRender.com/y29o453 ) and using a brain image from Adobe Stock. b , Photograph of the integrated soft ABI and its connectors: an Omnetics connector is embedded in a PEEK pedestal and connected to the soft ABI. An imaging marker and resorbable insertion spine are also visible. c , Integrated soft ECoG device: 29 electrodes (300-µm diameter) that record cortical signals. d , Close-up of the soft ABI: 11 electrodes (100-µm diameter). Right inset: FlexComb connector . e , f , In vitro characterization of the soft ABI ( e ) and EcoG ( f ). Left: EIS measurement, where data points represent the average and bars represent standard errors for all electrodes. Right: VT in response to a 100-µA biphasic current pulse. The thick blue line represents the average and light lines represent individual electrodes. g , Scanning electron microscopy (SEM) images of micropatterned ABI electrodes and interconnects. Top left: image of one ABI electrode and associated interconnect. Red frame, close-up of an interconnect; green frame, close-up of the electrode. Bottom right: colourized SEM of the electrode and encapsulation of <t>the</t> <t>platinum</t> layer within the polyimide dielectric layers.
    Platinum Iridium Ground Wire, supplied by A-M Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/platinum iridium ground wire/product/A-M Systems
    Average 90 stars, based on 1 article reviews
    platinum iridium ground wire - by Bioz Stars, 2026-06
    90/100 stars
      Buy from Supplier

    Image Search Results


    a , Left: schematic of an NHP brain. The soft ABI is implanted on the cochlear nucleus; the soft ECoG records cortical responses from the auditory cortex. Right: NHP behavioural task in response to electrical or acoustic stimulation. Created with BioRender.com ( https://BioRender.com/y29o453 ) and using a brain image from Adobe Stock. b , Photograph of the integrated soft ABI and its connectors: an Omnetics connector is embedded in a PEEK pedestal and connected to the soft ABI. An imaging marker and resorbable insertion spine are also visible. c , Integrated soft ECoG device: 29 electrodes (300-µm diameter) that record cortical signals. d , Close-up of the soft ABI: 11 electrodes (100-µm diameter). Right inset: FlexComb connector . e , f , In vitro characterization of the soft ABI ( e ) and EcoG ( f ). Left: EIS measurement, where data points represent the average and bars represent standard errors for all electrodes. Right: VT in response to a 100-µA biphasic current pulse. The thick blue line represents the average and light lines represent individual electrodes. g , Scanning electron microscopy (SEM) images of micropatterned ABI electrodes and interconnects. Top left: image of one ABI electrode and associated interconnect. Red frame, close-up of an interconnect; green frame, close-up of the electrode. Bottom right: colourized SEM of the electrode and encapsulation of the platinum layer within the polyimide dielectric layers.

    Journal: Nature Biomedical Engineering

    Article Title: High-resolution prosthetic hearing with a soft auditory brainstem implant in macaques

    doi: 10.1038/s41551-025-01378-9

    Figure Lengend Snippet: a , Left: schematic of an NHP brain. The soft ABI is implanted on the cochlear nucleus; the soft ECoG records cortical responses from the auditory cortex. Right: NHP behavioural task in response to electrical or acoustic stimulation. Created with BioRender.com ( https://BioRender.com/y29o453 ) and using a brain image from Adobe Stock. b , Photograph of the integrated soft ABI and its connectors: an Omnetics connector is embedded in a PEEK pedestal and connected to the soft ABI. An imaging marker and resorbable insertion spine are also visible. c , Integrated soft ECoG device: 29 electrodes (300-µm diameter) that record cortical signals. d , Close-up of the soft ABI: 11 electrodes (100-µm diameter). Right inset: FlexComb connector . e , f , In vitro characterization of the soft ABI ( e ) and EcoG ( f ). Left: EIS measurement, where data points represent the average and bars represent standard errors for all electrodes. Right: VT in response to a 100-µA biphasic current pulse. The thick blue line represents the average and light lines represent individual electrodes. g , Scanning electron microscopy (SEM) images of micropatterned ABI electrodes and interconnects. Top left: image of one ABI electrode and associated interconnect. Red frame, close-up of an interconnect; green frame, close-up of the electrode. Bottom right: colourized SEM of the electrode and encapsulation of the platinum layer within the polyimide dielectric layers.

    Article Snippet: The ECoG platinum ground wire (PFA-coated platinum wire (127 μm bare diameter); A-M Systems, 773000) with exposed tip was placed epidurally and below the skull in the frontal part of the craniotomy.

    Techniques: Imaging, Marker, In Vitro, Electron Microscopy, Encapsulation